Panel Type Electromagnetic Conductivity Analyzer MBM-100A Compact DIN 96 size Accurate measurements for high conductivity corrosive solutions (such as strong acid/alkali) 2-point contact signal, 4 - 20mA output (RS-232 optional) Meas. range Minimum : 0 - 2 mS/cm Maximum: 0 - 2000 mS/cm
Compact toroidal, heat resistant PVC type or Teflon detector with excellent corrosion resistance are available Accurate results for high conductivity corrosive solutions (such as strong acid/alkali) Types of detectors available: flow-through, immersion, pipeline insertion, drop-in, etc. Meas. range Minimum : 0 - 500 μS/cm Maximum: 0 - 2000 mS/cm
Toroidal type teflon detector with excellent corrosion/heat/pressure resistance Accurate results for high conductivity corrosive solutions (such as strong acid/alkali) Types of detectors available: flow-through, immersion, pipeline insertion, etc. Meas. range Minimum: 0 - 2 mS/cm Maximum: 0 - 2000 mS/cm
Panel type DO analyzer in a compact DIN 96 size One-touch calibration and various self-diagnostic functions 2-point contacts signal, 4 - 20mA output (RS-232 optional) Power supply: 90 - 264VAC, 50/60Hz Meas. range Minimum : 0 - 1 mg/L Maximum: 0 - 50 mg/L
Detector with Water Jet Cleaner JOC-711C / JOC-950C Cleaning electrode contamination by jetting water or air onto the electrode Immersion type (JOC-711C) and drop-in type (JOC-950C) Electrode: polarograph type 7533L (for standard use) or 7536L (for human waste)